Thiết bị đo Original Honeywell RTD STT170 series of programmable temperature transmitters STT3000
Original Honeywell RTD STT170 series of programmable temperature transmitters STT3000
The Honeywell STT170 series of programmable temperature transmitters provides cost effective solutions for temperature
monitoring applications. Compared to direct-wired temperature sensor monitoring points, the STT170 series of transmitters delivers increased accuracy, safety and reliability while also reducing wiring costs. These transmitters automatically linearize the temperature output signal bounded by the upper range value and lower range value established by the user. In addition, the user can program high or low limit alarms to activate in the case of sensor failure.
STT171 FEATURES
• Analog 4-20 mA output
• RTD or Ohm input
• DIN form B headmount
• NAMUR NE43 sensor error response
• Configurable using STT17C configuration tool and PC
STT170 is a measurement solution for temperature monitoring applications. It helps end users and Original Equipment Manufacturers (OEMs) achieve reliable and accurate temperature measurement in a cost-effective manner.
The STT170 is Honeywell’s economy-tier family of temperature transmitters to flank the existing mid-tier STT250 and high-tier STT350 temperature transmitters. It helps convert low level signals from temperature sensors such as RTDs and TCs into current signals and is capable of transmitting long distances through noisy plant environments. The STT170 line consists of four temperature transmitters and one configuration tool:
STT171 – Analog output, RTD-only sensor input
STT173 – Analog output, RTD or thermocouple sensor input
STT17H – HART output, RTD & thermocouple sensor input
STT17F – FOUNDATION Fieldbus protocol, RTD & thermocouple sensor input
STT17C – PC-based configuration tool for configuring the STT171, STT173 and STT17H transmitters
Instructions
- Choose Availability column based on Key Number.
- A dot (.) denotes unrestricted availability.
- Select the desired Key Number based on the desired communications protocol.
- Select options and approvals from Tables.
Key Number
Description | Selection | Availability | ||||
4-20mA Output, RTD input 4-20mA Output, universal input HART Protocol, 4-20mA output Digital output, Foundation Fieldbus protocol Configuration tool for STT171, 173 and 17H |
STT171 STT173 STT17H STT17F STT17C |
|
|
|
|
|
Table I – Safety Approvals
Approval Body | Approval Type | Location or Classification | ||||||
None | No approval body certifications included | 00 | ● | ● | ● | ● | ● | |
FM, CSA, ATEX |
Intrinsically Safe ENTITY Non-Incendive |
Class I, Div. 1, Groups A,B,C,D, T4 Class I, Zone 0/1; AEx ia IIC, T4 Class I, Div. 2, Groups A,B,C,D, T4 |
BS | ● | ● | ● | ● | |
Intrinsically Safe ENTITY Non-Incendive |
Class I, Div. 2, Groups A,B,C,D, T4 Class I, Zone 0/1; Ex ia IIC, T4 Class I, Div. 2, Groups A,B,C,D, T4 |
|||||||
* Intrinsically Safe Zone 0/1 |
Ex II 1 GD, EEx ia IIC, T4..T6 Ex II 2 (1) GD, T4..T6 |
|||||||
Non-Incendive Zone 2 |
Class I, Div. 2, Groups A,B,C,D, T4 Ex II 3 G, EEx nA [L] T4..T6 |
BN | ● | ● |
When installed in Field Mount Enclosure Table IV, E _ _, or T _ _
FM Approval |
Intrinsically Safe ENTITY Non-Incendive |
Class I, Div. 1, Groups A,B,C,D, T4 Class I, Zone 0/1; AEx ia IIC, T4 Class I, Div. 2, Groups A,B,C,D, T4 |
1G | e | e | e | e | |
CSA |
Intrinsically Safe ENTITY Non-Incendive |
Class I, Div. 2, Groups A,B,C,D, T4 Class I, Zone 0/1; Ex ia IIC, T4 Class I, Div. 2, Groups A,B,C,D, T4 |
2G | e | e | e | e | |
ATEX |
* Intrinsically Safe Zone 0/1 |
Ex II 1 GD, EEx ia IIC, T4..T6 Ex II 2 (1) GD, T4..T6 |
3S | e | e | e | ||
Non-Incendive Zone 2 |
Class I, Div. 2, Groups A,B,C,D, T4 Ex II 3 G, EEx nA [L] T4..T6 |
3N | e |
* Ex II GD or II 2 (1) GD allows for installation in potentially explosive atmospheres caused by the presence of combustible dusts only when mounted in a metal enclosure of form B according to DIN 43729 (Head-Mount enclosure) that provides a degree of protection of at least IP 6X in accordance with EN 60529, that is suitable for the application and is correctly installed.
TABLE II – No Option
No Option | 0 | ● | ● | ● | ● | ● |
TABLE III – Configuration & Certificates
Configuration |
None – Factory Default Configuration Supplied Custom Transmitter Configuration with Printed Report ** |
0 _ _ T _ _ |
● ● |
● ● |
● ● |
● ● |
●
|
Calibration | Custom Transmitter Calibration with Printed Report ** | C _ _ | ● | ● | ● | ||
Optional Certificates | No Option | _ 0 _ | ● | ● | ● | ● | ● |
No Certificate of Conformance/Origin Certificate of Conformance/Origin |
_ _ 0 _ _ R |
● ● |
● ● |
● ● |
● ● |
1, First, send us the brand, model code/pic of the nameplate, the quantity for inquiry. Then we will send the quote to you. after confirming the model and the quantity, then we will the PI to you.
2, You can transfer by Paypal/ Western Union/Trade assurance/ T/T. When we received the payment, then we will start to prepare the order for you asap.
A: Yes, we provide a warranty for all the goods from us.
A: We’re in this field for more than 8 years. If there’s any problem, please contact with us, we’ll provide a suggestion from our
engineer to help you solve the problem.
A: We have a large warehouse for goods. Keep lots of goods in the warehouse, so could promise a fast delivery.
A: We provide you small MOQ for each item, it depends on your specific order!
.
A: We keep good quality and competitive price to ensure our customers benefit ;