Mô đun Schneider Modicon Quantum PLC 140CPU65150 UNITY PROCESSOR 768KB 166MHZ AVAILABLE
đại lý 140CPU65150 | nhà phân phối 140CPU65150
Description of Schneider Modicon Quantum PLC 140CPU65150 UNITY PROCESSOR 768KB 166MHZ AVAILABLE
Quick Details:
- SCHNEIDER ELECTRIC
- MODICON
- 140CPU65150
- UNITY PROCESSOR
- QUANTUM
- 768KB
- 166MHZ
- AVAILABLE
-
One Year Warranty
SPECIFICATION
Manufacturer | Schneider Electric |
Series | Modicon Quantum |
Module format | Standard |
Product or component | Unity processor |
Clock frequency | 166 MHz |
Number of slots | 10 |
16 | |
2 | |
4 | |
6 | |
Number of racks | 2 – local rack(s) |
Number of distributed I/O station | 63 station(s) – 1 rack(s) – 3 distributed network(s) |
Number of remote I/O station | 31 – 2 remote rack(s) |
Discrete I/O number | 8000 inputs, 8000 outputs – distributed – per network |
31744 inputs, 31744 outputs – remote | |
Unlimited (26 slots max) – local | |
Analogue I/O number | Unlimited (26 slots max) – local |
500 inputs, 500 outputs – distributed – per network | |
1984 inputs,1984 outputs – remote | |
Application specific I/O | Accurate time stamping |
Counter | |
High-speed interrupt inputs | |
Serial link | |
Number of optional modules | 6 (Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
Maximum number of connections | Unlimited (AS-Interface) – local |
6 (Profibus DP) – local | |
6 (Modbus Plus) – local | |
6 (Ethernet TCP/IP) – local | |
4 (AS-Interface) – remote | |
2 (AS-Interface) – distributed | |
1 (USB) | |
1 (Modbus) – RS232/485 Modbus/ASCII | |
Integrated connection type | 1 Ethernet TCP/IP |
1 Modbus | |
1 Modbus Plus | |
1 USB | |
Checks | Process control |
Memory description | Expandable 8 MB – file storage with PCMCIA card |
Expandable 7168 kB – program with PCMCIA card | |
Internal RAM 768 kB |
Switch function | Key switch memory port on/off |
Application structure | 4 auxiliary tasks |
32 timer interrupt tasks | |
128 interrupt tasks | |
128 I/O interrupt tasks | |
1 periodic fast task | |
1 cyclic/periodic master task | |
Execution time per instruction | 0.48…0.56 µs floating points |
0.0525…0.075 µs Boolean | |
0.045…0.06 µs on word | |
0.045…0.06 µs on fixed-point arithmetic | |
Execution time for 1 K instruction | 9.91 65 % Boolean and 35 % numerical |
10.28 100 % Boolean | |
System overhead | 1 ms – master task |
0.2 ms – fast task | |
Bus current requirement | 2160 mA |
Local signalling | 1 LED red for Ethernet collision |
1 LED green for Ethernet activity (COM) |
Introduce for Quantum PLC module
Quantum PLC module USES modern large-scale integrated circuit technology, after strict production process manufacturing, the internal circuit adopted advanced anti-interference technology, so it has very high reliability. Quantum PLC also with hardware fault self-detection function, failure can be timely alarm information. And can be programmed in the Concept of peripheral components of the fault self-diagnosis program, so that the system in addition to THE PLC circuit and equipment also obtain fault self-diagnosis protection, so that the whole system has high reliability. All modules can be plugged and plugged on, no need to stop the system, reduce the workload, easy to maintain. LED status indicator shows the CPU and its I/O template channel status visually, which provides great convenience for quick maintenance.
Quantum PLC has complete supporting facilities, complete functions and strong applicability. The important systems such as river water intake and condensate fine treatment adopt double machine heat backup, redundant power supply, redundant remote I/O, plus double Ethernet to ensure the safe and continuous operation of the system. Especially the advanced two – machine hot – standby system has simple configuration and convenient operation. Through two sets of modules with identical configuration, the form of primary and secondary is formed. Under normal state, the host CPU is responsible for processing program operation, I/O communication, update the status and data of the standby CPU through the hot standby module, and the standby machine monitors the running status of the host. When the host machine fails, the standby machine will switch immediately and become the host machine to replace the processing work of the failed machine. Moreover, the switching time is short and will not exceed a scanning cycle of PLC, so the logic operation will not be affected.
Our products are widely used in CNC machinery, metallurgy, petroleum and natural gas, petrochemical, chemical, paper printing, textile printing and dyeing, machinery, electronic manufacturing, automobile manufacturing, tobacco, plastic machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, transmission and distribution industries.
Introductionof Technology CO.,LTD
OTHER SUPERIOR PRODUCTS of Technology CO.,LTD
Yasakawa Motor, Driver SG- |
Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- |
Emerson VE-,KJ- |
Honeywell TC-,TK- |
GE Modules IC – |
Yokogawa transmitter EJA- |
of Technology CO.,LTD
1.
2.
3.
.
1.
2.
3.
* Passionate, experienced and highly-educated R & D and sales team;