Mô đun Westinghouse Emerson Ovation Processor Module 5X00241G01
đại lý 5X00241G01 | nhà phân phối 5X00241G01
Westinghouse Emerson Ovation Processor Module 5X00241G01
Brand: | EMERSON |
---|---|
Condition: | Used |
Model: | 5X00241G01 |
Weight: | 0.60 lbs |
Dimensions: | 4.75 x 6.50 x 2.00 in |
SKU: | R701403 (WP3-A) |
Category: |
Input Modules
|
Emerson 5X00241G01
Description: Remote I/O
Model Number: 5X00241G01
Category: Other
Warranty: 12 months
Delivery Options: Standard, Express, Same Day & Next Day options available
Manufactured by EMERSON
WESTINGHOUSE PROCESS CONTROL
- EMERSON
- WESTINGHOUSE PROCESS CONTROL
- 5X00241G01
- DISCONTINUED BY MANUFACTURER
- ANALOG OUTPUT 0-20MA ELECTRONIC MODULE
- AVAILABLE
- REBUILT SURPLUS
- NEVER USED SURPLUS
- REPAIR YOURS
- 24-48 HOUR RUSH REPAIR
- 2 – 15 DAY REPAIR
- 2 YEAR RADWELL WARRANTY
Product Details
EMERSON 5X00241G01OVATION HART ANALOG INPUT MODULE
-
Emerson Ovation HART Analog Input Module (5X00241G01)
-
Manufacturer: Emerson
-
Series: Ovation
Westinghouse DCS system description:
DCS is abbreviation of Distributed Control System, which is called Distributed Control System in ‘s domestic automatic control industry. It is a multi-level computer system composed of process control level and process monitoring level as the link of communication network. It integrates computer Computer, Communication, CRT and Control 4C technology. The so-called distributed control system, or in some information called the distributed system, is a new type of computer control system relative to the centralized control system, which is based on the centralized control system developed, evolved Come on. It is a multi-level computer system composed of process control level and process monitoring level with communication network as the link, which integrates 4C technology such as computer, communication, display and control. Its basic idea is decentralized control, centralized operation, hierarchical management, Configuration flexibility and configuration convenience. In terms of system functions, DCS and centralized control system is not very different, but in the realization of system functions are completely different, first of all, DCS skeleton – system network, which is the basis and core DCS. As the network for the DCS real-time system as a whole, reliability and scalability, plays a decisive role, so all manufacturers are carefully designed in this regard. For the DCS system network, it must meet the real-time requirements, that is, within a certain time limit to complete the transfer of information. The “definite” time limit here means that in any case, the transmission of information can be completed within this time limit, which is determined according to the real-time requirements of the controlled process. Therefore, the indicator that measures the performance of the system network is not the rate of the network, commonly referred to as the number of bits per second (bps), but the real-time nature of the system network, that is, how long to ensure that the required information is transmitted . The system network must also be very reliable, in any case, network communication can not be interrupted, so most manufacturers are DCS dual-bus, ring or dual star network topology. In order to meet the requirements of system expansion, the maximum number of nodes that can be accessed on the system network should be several times larger than the actual number of nodes. In this way, on the one hand, new nodes can be added at any time, and on the other hand, the system network can be operated at a light communication load to ensure the real-time and reliability of the system. In actual operation of the system, the access to and access to the Internet at various nodes may happen at any time, especially the operator station. In this way, the network reconfiguration will be carried out frequently, and this operation absolutely can not affect the normal operation of the system. Therefore, the system The network should have strong online network reconfiguration capabilities.
Westinghouse DCS system features:
Centralized management
Scattered control
High reliability
Openness
Flexible configuration
Configuration is convenient
Flexible control
1C31116G04 Ovation Emerson DCS | 4256A25G01 / 1C31025G03 | 4256A64G02 / G50 | 4256A66G01 | ||||
1B30035H01 Ovation Emerson DCS | 4256A26G01 | 4256A64G05 | 4256A67G01 | ||||
5X00109G02 Ovation DCS System | 4256A41G01 | 4256A65G02 | 4256A84G03 / 3A99159G03 | ||||
5X00106G01 Ovation DCS System | 4256A41G01 | 4256A65G05 | 4256A88G04 | ||||
1C31197G01 Ovation DCS System | |||||||
1C31194G01 Ovation DCS System | 4256A91G03 | 4256A97G01 | 4A00081G01 | ||||
1C31197G05 Ovation DCS System | 4256A93G01 | 4256A98G01 | 4A00081H01 | ||||
1C31194G03 Ovation DCS System | 4256A94G01 | 4256A99G02 | 4D33613G01 | ||||
1C31166G02 Ovation DCS System | 4256A96G01 | 4626B58G03 | 4D33613G02 | ||||
5X00270G01 Ovation DCS System | 4256A96G02 | 4620B91G01 | 4D33644G02 | ||||
5X00059G01 Ovation DCS System | |||||||
1C31179G02 Ovation DCS System | 4D33755G04 | 4D33865G03 | 5A26391H03 | ||||
1C31113G05 westinghouse ovation | 4D33811G01 | 4D33913G01 | 5A26433H01 | ||||
5X00489G01 westinghouse ovation | 4D33811G02 | 4D33913G02 | 5A26434H01 | ||||
1C31110G03 westinghouse ovation | 4D33865G01 | 4D33916G01 | 5A26457G01 | ||||
5X00300G01 westinghouse ovation | 4D33865G02 | 5A23307H15 | 5A26458G01 | ||||
1C31116G01 westinghouse ovation | |||||||
5X00419G02 westinghouse ovation | 5A26458G01 | 5X00070G04 | 5X00121G01 | ||||
5X00419G01 westinghouse ovation | 5D32123G02 | 5X00105G07 | 7379A06G02 | ||||
5X00167G01 westinghouse ovation | 5D32191G01 | 5X00105G14 | 7379A21G01 | ||||
1C31150G01 westinghouse ovation | 5X00058G01 | 5X00117H03 | 7379A21G02 / 3A99164G02 / 3A99164G50 | ||||
1X00188H01 westinghouse ovation | 5X00059G01 | 5X00119G01 | 7379A29G01 | ||||
5X00226G02 Ovation Controller | |||||||
1X00024H01 WH1-2FF Ovation Controller | 7379A62G01 | 7379A92G02 | 7380A36G01 | ||||
5X00105G14 Ovation Controller | 7379A62G02 | 7379A92G02 | 7380A37G02 | ||||
5X00121G01 Ovation Controller | 7379A84G01 | 7379A92G03 | 7380A43G01 | ||||
1C31116G01 Ovation Controller | 7379A89G01 | 7379A93G01 | 7380A51G01 | ||||
1C31110G03 Ovation Controller | 7380A92G04 | 7380A29G03 | 7380A70G02 | ||||
5X00489G01 Ovation Controller | |||||||
1C31116G04 Ovation Controller | 7381A01G01 / 772B388G01 | 7381A10G03 | 7381A34G02 | ||||
1C31197G01 Ovation Controller | 7381A01G02 / 773B388G21 | 7381A28G02 | 7381A61G01 | ||||
1C31233G04 Ovation Controller | 7381A01G03 | 7381A29G01 | 7381A61G02 | ||||
1C31142G01 Ovation Control System | 7381A01G04 / 772B388G51 | 7381A29G05 | 7381A73G01 | ||||
1X00102H01 Ovation Control System | 7381A08G01 / 772B400G04 | 7381A34G01 | 7381A81G01 | ||||
5X00300G01 Ovation Control System | |||||||
5X00419G01 Ovation Control System | 772B217G02 | 772B387G01 | 4256A90G01 | ||||
5X00419G02 Ovation Control System | 772B379G01 / 7380A27H01 | 772B450G01 | 4256A90G02 | ||||
IC31224G01 Ovation Control System | 772B379G01 | 772B450G02 | 4256A91G01 | ||||
1C31222G01 Ovation Control System | 9690A38G38 | 772B452G01 | 4256A91G02 | ||||
5X00109G02 Ovation Control System | |||||||
1C31219G01 Ovation Control System | 7379A31G01 | 7380A72G01 | 4D33644G04 | ||||
1C31194G01 Ovation Control System | 7379A31G02 / 3A99165G02 | 7380A78G01 | 4D33644G06 | ||||
1P00028G01 EMERSON OVATION DCS | 7379A31G03 / 3A99165G03 / 3A99165G50 | 7380A84H01 | 4D33645G05 | ||||
1C31223G01 EMERSON OVATION DCS | 7379A31G04 | 7380A92G02 | 4D33743G01 | ||||
5X00070G04 EMERSON OVATION DCS | 7379A31G05 | 7380A92G03 | 4D33755G01 |
Westinghouse DCS distributed control system applications:
Thermal power plant, petrochemical, chemical, steel, metallurgy, nuclear power and other industries
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
Website:www.wtltian.com