Mô đun Schneider Electric Input Module 140DAI75300 PV 03 RL 07 AC Input 230 95 % without condensation
Schneider Electric Input Module 140DAI75300 PV 03 RL 07 AC Input 230 95 % without condensation
Configuration
• Two- or three-, fusible switched poles-, with or without, insulated groundable solid neutral
• Four- or six-, fusible switched poles-, without insulated, grounded, solid
neutral
• Two-, three-, four-, or six-, non-fusible switched poles-, without
insulated, grounded, solid neutral
• Three, fusible switched poles-, without insulated, grounded, solid neutral, interlocked to Appleton, Crouse-Hinds, or Hubbellock
receptacle
• Three, non-fusible switched poles, without insulated, grounded, solid neutral-, interlocked to Appleton, Crouse-Hinds, or Hubbellock
receptacle
4.9…0.75 ms x line cycle Off-On
7.3…12.3 ms On-Off
isolation between group
1780 Vrms for 1 minute
isolation between group and bus
1780 Vrms for 1 minute
bus current requirement
250 mA
maximum power dissipation in W
5 W
local signalling
1 LED (green)bus communication is present (Active):
1 LED (red)external fault detected (F):
32 LEDs (green)input status:
marking
CE
module format
Standard
net weight
0.3 kg
Environment
standards
CSA C22.2 No 142
UL 508
product certifications
FM Class 1 Division 2
CUL
resistance to electrostatic discharge
4 kV contact conforming to IEC 801-2
8 kV on air conforming to IEC 801-2
resistance to electromagnetic fields
10 V/m 80…2000 MHz conforming to IEC 801-3
ambient air temperature for operation
0…60 °C
ambient air temperature for storage
-40…85 °C
relative humidity
95 % without condensation
operating altitude
<= 5000 m
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
RoHS Regulation
RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Standards
Heavy duty safety switches are manufactured in accordance with these standards:
• UL98, Standard for enclosed and dead front switches. UL Listed;
— 30–200 A, see file E2875
— 400–1200 A, see file E154828
• NEMA Standards Publication KS1 and KS2 enclosed switches
• Federal Specifications WS-865C for Type HD
• Visible blades for positive blade position indication
• Optional viewing window allows visual verification of blade position without opening door; not available on NEMA Type 4X fiberglass
reinforced polyester enclosures or NEMA Type 7/9 enclosures
• Red and black handle indicates the ON (red) or OFF (black) switchposition – except NEMA Type 7/9 enclosures
• Series F handle, mechanism and lock plate are field replaceable
• Side-opening, left hinged covers
• Highly visible embossed ON-OFF marking / ON-OFF labels are used on NEMA Type 4X fiberglass reinforced polyester enclosures
• Quick-make, quick-break, operating mechanism
• Standard with plated aluminum lugs which accept both Cu and Al wires
• Front removable mechanical lugs
• Dual cover interlock prevents the cover from being opened when the switch is ON and prevents the switch from being turned ON when the
cover is open
• An interlock bypass is provided for access by authorized personnel
140EHC10500
140EHC20200
140ERT85410
140NOM21100 MB+
140XTS00200
140XBE10000
140XCA71703
140XCA71706
140XCP51000
416NHM30030A MB+
490NAA27102 MB+
490NAA27103 MB+
490NRP25300 Modbus Plus
490NRP95400 RIO
490NOR00003 Ethernet MTRJ-MTRJ
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |