Mô đun Schneider Electric 140NOL91120 Controller PLC with LED display
đại lý 140NOL91120 | nhà phân phối 140NOL91120
Schneider Electric 140NOL91120 Controller PLC with LED display
range of product |
Modicon Quantum automation platform
|
|
---|---|---|
product or component type |
Ethernet network TCP/IP module
|
|
concept |
Transparent Ready
|
|
web server |
Class B30
|
|
web services |
Diagnostics via predefined web pages
Rack viewer Data Editor (via PC terminal) |
|
communication service |
SNMP network management
Bandwidth management Global Data I/O scanning Modbus TCP messaging FDR server |
|
communication port protocol |
Ethernet Modbus TCP/IP
|
|
physical interface |
MT/RJ – 100BASE-FX fiber optic
RJ45 – 10BASE-T/100BASE-TX twisted pair |
|
transmission rate |
10/100 Mbit/s
|
redundancy |
Yes hot standby redundant architecture
|
|
---|---|---|
supply |
Via the power supply of the rack
|
|
marking |
CE
|
|
local signalling |
1 LED10 Mbps or 100 Mbps data rate (10 MB/100 MB):
1 LEDcollision detection (Coll): 1 LEDdownload mode (Kernel): 1 LEDEthernet module fault (Fault): 1 LEDEthernet network status (RUN): 1 LEDfull-duplex mode (Fduplex): 1 LEDmodule ready (Ready): 1 LEDnetwork active (Link): 1 LEDrack operational (Active): 1 LEDtransmission/reception activity (TxAct/RxAct): |
|
current consumption |
750 mA at 5 V DC
|
|
module format |
Standard
|
|
net weight |
0.345 kg
|
IP degree of protection |
IP20
|
|
---|---|---|
product certifications |
CUL
UL 508 |
|
standards |
CSA C22.2 No 142
FM Class 1 Division 2 |
|
resistance to electrostatic discharge |
4 kV contact conforming to IEC 801-2
8 kV on air conforming to IEC 801-2 |
|
resistance to electromagnetic fields |
10 V/m 80…1000 MHz conforming to IEC 801-3
|
|
ambient air temperature for operation |
0…60 °C
|
|
ambient air temperature for storage |
-40…85 °C
|
|
relative humidity |
95 % without condensation
|
|
operating altitude |
<= 4500 m
|
Similar Model Products
Analog I/O modules | Discrete I/O modules | ||
140ACI03000 | 140DDI15310 | 140DAI55300 | 140DAO84210 |
140ACI04000 | 140DDI35300 | 140DAI74000 | 140DAO84220 |
140ACO02000 | 140DDI35310 | 140DAI75300 | 140DAO85300 |
140ACO13000 | 140DDI36400 | 140DSI35300 | 140DRA84000 |
140AII33000 | 140DDI67300 | 140DDO15310 | 140DRC83000 |
140AII33010 | 140DDI84100 | 140DDO35300 | 140DVO85300 |
140AIO33000 | 140DDI85300 | 140DDO35301 | 140DDM39000 |
140AMM09000 | 140DAI34000 | 140DDO35310 | 140DDM69000 |
140ARI03010 | 140DAI35300 | 140DDO36400 | 140DAM59000 |
140ATI03000 | 140DAI45300 | 140DDO84300 | 140DII33000 |
140AVI03000 | 140DAI54000 | 140DDO88500 | 140DIO33000 |
140AVO02000 | 140DAI54300 | 140DAO84000 | 140DAO84010 |
(1) CPUs updated with the Unity Pro firmware.
(2) The addition of a complete Ethernet RIO drop function is available for these CPUs with
Unity Pro u V7.0.
ConneXium™ managed switches (continued) Predefined configuration files (continued) Example topology with predefined configuration files C5, C1 and C3 (1) A common use of this preconfiguration is for interfacing a copper link with a fiber optic link on the primary ring or interfacing a fiber optic link with a copper link. This type of architecture makes it possible to have Ethernet DIO or Ethernet RIO drops some distance away from the PLC. The switch preconfiguration also enables Ethernet RIO and/or several Ethernet DIO device clouds to be connected to a secondary ring.
1 Primary ring, copper/fiber optic medium
3 Ethernet head adaptor 140NOA61100 installed in the Quantum™ rack.
4 ConneXium switch TCSESM083F23F1 with predefined configuration file C2 (2)
5 ConneXium switch TCSESM063F2CU1/CS1 with predefined configuration file C6 (2)
6 ConneXium switch TCSESM063F2CU1/CS1 with predefined configuration file C4 (2)
7 Modicon™ STB Ethernet DIO (3) (4)
8 Connection to Ethernet DIO device cloud, copper medium only
9 Ethernet DIO device cloud (3)
10 Ethernet communication module 140CPU31110
11 Ethernet Interlink cable TCSECN3M3M1S4/1S4U (1 m)
- melody
- Telephone:-13714157127