Mô đun IC693ALG223 Redundant Power Supply Module PLC Module INPUT ANALOG 16 PT CURRENT
Redundant Power Supply Module GE Fanuc IC693ALG223 PLC Module INPUT ANALOG 16 PT CURRENT
Number of Channels 1 to 16 selectable; single ended
Input Current Ranges 0 to 20 mA, 4 to 20 mA and 4 to 20 mA Enhanced (selectable per channel)
Calibration
Factory calibrated to:
4 µA per count on 4 to 20 mA range
5 µA per count on 0 to 20 mA and 4 to 20 mA Enhanced range
Update Rate 13 msec (all 16 channels)
Resolution at 4-20 mA 4 µA (4 µA/bit)
Resolution at 0-20 mA 5 µA (5 µA/bit)
Resolution at 4-20 mA Enhanced 5 µA (5 µA/bit)
Absolute Accuracy
± 0.5% of full scale over specified operating temperature range
Linearity
< 1 LSB from 4 to 20 mA (4 to 20 mA range) < 1 LSB from 100 µA to 20 mA (0 to 20 mA and 4 to 20 mA Enhanced ranges)
Isolation 1500 volts between field side and logic side
Common Mode Voltage 0 volts (single-ended channels)
Cross-Channel Rejection> 80 db from DC to 1 kHz
Cross-Channel Rejection 80 db from DC to 1 kHz Input Impedance
Input Impedance 250 ohms
Input Low Pass Filter Response 19 Hz
External Supply Voltage Range 20 to 30 VDC
External Supply Voltage Ripple 10%
Analog Current Input – 16 Channel
IC693ALG223
The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each
capable of converting an analog input signal to a digital value for use as required by your
application. This module provides three input ranges:
4 to 20 mA
0 to 20 mA
4 to 20 mA Enhanced
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Similar Products
IC697ACC621
IC697ACC624
IC697ACC644
IC697ACC700
IC697ACC701
IC697ACC702
IC697ACC715
IC697ACC720
IC697ACC721
IC697ACC722
IC697ACC723
IC697ACC724
IC697ACC726
IC697ACC727
IC697ACC728
IC697ACC729
IC697ACC730
IC697ACC732
IC697ACC735
IC697ACC744
IC697ACC775
IC697ACC800
IC697ACC801
IC697ACC802
IC697ACC803
IC697ACC804
IC697ACC805
IC697ACC820
IC697ACC821
IC697ACC822
IC697ADC701
IC697ADC701RR
IC697ADS701
IC697ALG230
IC697ALG230RR
IC697ALG234
IC697ALG320
IC697ALG320RR
IC697ALG324
IC697ALG440
IC697ALG440RR
IC697ALG441
IC697ALG441RR
IC697ALG444
Current Ranges
The default range is 4 to 20 mA with user data scaled so that 4 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000. The other ranges are selected by changing the configuration parameters using the IC641 configurator software or the Hand-Held Programmer. The range can be configured so that the input range is 0 to 20 mA with user data scaled so that 0 mA corresponds to a count of 0 and 20 mA corresponds to a count of 32000. Full 12-bit resolution is available over the 4 to 20 and 0 to 20 mA ranges.
A 4 to 20 mA Enhanced range can also be selected. When this range is selected, 0 mA corresponds to a count of –8000, 4 mA corresponds to a count of 0 (zero) and 20 mA corresponds to a count of +32000. The Enhanced range uses the same hardware as the 0 to 20 mA range but automatically provides 4 to 20 mA range scaling with the exception that negative digital values are provided to the user for input current levels between 4 mA and 0 mA. This gives you the capability of selecting a low alarm limit that detects when the input current falls from 4 mA to 0 mA, which provides for open-wire fault detection in 4 to 20 mA applications. High and Low alarm limits are available on all ranges. Ranges can be configured on a per channel basis. The module also reports module status and user-side supply status to the CPU.
Power Requirements and LEDs
This module consumes 120 mA from the 5V bus on the PLC backplane and also requires 65 mA
plus current loop current(s) from a user supplied +24V supply (see Table 3-13, Specifications).
There are two green LED indicators on the module which provide module and user supply
status. The top LED, MODULE OK provides module status information on power-up as
follows:
ON: status is OK, module configured;
OFF: no backplane power or software not running (watchdog timer timed out);
Continuous rapid flashing: configuration data not received from CPU;
Slow flashes, then OFF: failed power-up diagnostics or encountered code execution error.
The bottom LED, User Supply OK, indicates that the user provided 24V supply is within
specifications, thereby enabling the analog side of the module to work properly.
Location in System
This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC
system
References Used
The number of 16-Channel Analog Current Input modules which may be installed in a system
depends on the amount of %AI and %I references available. Each module uses 1 to 16 %AI
references (depending on the number of channels enabled) and from 8 to 40 %I (depending on
alarm status configuration) references.
The number of 16-Channel Analog Current Input modules which may be installed in a system
depends on the amount of %AI and %I references available. Each module uses 1 to 16 %AI
references (depending on the number of channels enabled) and from 8 to 40 %I (depending on
alarm status configuration) references.
The available %AI references are: 64 in a Model 311, Model 313, and Model 323 system, 128
in a Model 331 system, 1024 in a Model 340 and 341 system, and 2048 in a Model 351 and
Model 352 system.
The maximum number of 16-Channel Analog Current Input modules which may be installed in a
system are:
4 in a Model 311, Model 313, and Model 323 system
8 in a Model 331 system
12 in a Model 340 and Model 341 system
51 in a Model 351 and Model 352 system
When planning the module configuration for your appl
When planning the module configuration for your application you must also consider the load
capacity of the installed power supply and the total load requirements of all modules that are
installed in the baseplate.
Refer to the Series 90-30 Programmable Controller Installation Manual, GFK-0356 for details on
power supplies and module load requirements.