Mô đun Ge Fanuc IC660BBS103 , eight circuit I/O isolated block , 115 VAC or 125 VDC
đại lý IC660BBS103 | nhà phân phối IC660BBS103
Ge Fanuc IC660BBS103 , eight circuit I/O isolated block , 115 VAC or 125 VDC
Product Description
The IC660BBS103 is an eight circuit I/O isolated block by GE Fanuc. The block has a rated voltage of 115 VAC or 125 VDC with an input voltage range of between 93 VAC and 132 VAC. Output voltage range varies from 105 to 132 VDC with a load current of two Amps for every output point.
The IC660BBS103 block’s isolation can withstand a voltage of 250 VAC or VDC between two groups or between a group and a ground. It has a transient rating of 2000V for every 10 seconds.
The block can be powered differently from the circuits with power being either AC or DC. The block’s control power can be tapped from the voltages of input/output devices which are wired to the terminals. There is electronic fusing for every circuit used for output. The circuit shuts down immediately after five microseconds in the event of a short circuit. The circuit can thereafter be restarted using a handheld monitor or a CPU. Some of the diagnostic checks include detection of sudden shutdowns, voltage overload, overheating, and detection of power loss to the circuits.
During block mounting, it is advisable to mount the block in a protective enclosure, clean and free from contaminants. It can be mounted facing up or down. It is important to leave two inches of space between blocks for ample ventilation. During field wiring, all terminals will accept 1 AWG #12 wire or 2 AWG #14 wires. The minimum wire size recommended is AWG #22. Ring terminals of up to 0.27 inches can be accommodated by the block. The recommended torque for the terminal screws is 0.678 N/M.
Operating temperature for IC660BBS103 ranges from 0-60o C with storage temperature being -40o C to 80o C.
Rated Voltage: | 115 VAC / 125 VDC |
# of Points: | 8 |
Input Voltage Range: | 93 – 132 VAC |
Output Voltage Range: | 105 – 132 VDC |
Load Current per Point: | 2.0 Amps |
Points per Common: | Four groups of 2 |
Technical Information
Specifications
Block Type: 115VAC/125VDCIsolatedI/OBlock: Terminal Assembly Only: ElectronicsAssemblyOnly: 115VAC / 125VDCIsolatedI / OBlock,NoFailed Switch: Terminal Assembly Only: ElectronicsAssemblyOnly: |
8cktisolatedinput/outputin4isolatedpairs IC660BBS102, replaces IC660BBS100 IC660TSS100 IC660EBS100 IC660BBS103, replaces IC660BBS101 IC660TSS100 IC660EBS101 |
Size (height x width x depth): Weight: LED’s (I/O Block): LED’s (each circuit): Block to BlockIsolation: HeatDissipation: |
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” x (10.00cm) 4 lbs. (1.8 kg) Unit OK, I / OEnabled On logic side of switch 1500 V 16.8W max. with 8 inputs on, 45.6W max. with 8 outputs at 2 amps |
Operating Temperature Storage Temperature Humidity Vibration |
–0 to +60C (32 to +140F) –40 C (–40 to +212F) 5% to 95% (non–condensing) 5–10 Hz 0.2” (5.08mm) displacement, 10–200 Hz at 1G |
Required control power (block only): Operating voltage (four sources): Frequency/ripple: Power supply dropout time: |
8 Wattsmaximum |
93–132VAC105–132VDC 47–63Hz10% max.ripple 1cycle10mS |
|
Input Characteristics: Non–tristate input, OFF state: Minimum voltage across input device (IN to H) Maximum leakage through input device Non–tristate input, ON state: Maximumvoltageacrossinputdevice(INtoH) Maximumswitchcurrentthreshold Tristate input: OFF, acceptable voltage across input device (IN to H) ON, maximum voltage across input device (IN to H) Input load network: Resistor to N Capacitor to H: for blocks BBS100 and BBS101 Capacitor to H: for blocks BBS102 and BBS103 Input processing time (typical) Selectable input filter times Inputdiagnostics |
ForACForDC 60VRMS70VDC 1mA2mA 20VRMS35VDC 6mARMS5mA 16VRMS–40VRMS16 VDC–35VDC 4VRMS3.5VDC 13Kohms13Kohms .22ïf.22ïf .1ïf.1ïf 2mS+filter0.8mS +filter |
10 to 100mS in 10mS increments Open Wire, Overtemperature, Loss of I / O Power, Failed Switch |
|
OutputCharacteristics: Output current (steady state) Maximum inrush current Output Leakage: Current at 0 volt output: for blocks BBS102 and 103 Current at 0 volt output: for blocks BBS100 and 101 Voltage at open output: for blocks BBS102 and 103 Voltage at open output: for blocks BBS100 and 101 Output switch (OFF to ON / ON to OFF) Rated switching frequency at maximum inrush Turn–on delay (maximum) Voltage drop (at 2 amps) Voltage drop (at 20 amps inrush) Minimum load (No Load disabled) Resistive: for blocks BBS102 and BBS103 Resistive: for blocks BBS100 and BBS101 Inductive: for blocks BBS102 and BBS103 Inductive: for blocks BBS100 and BBS101 No Load enabled threshold Maximum block output current Fusing Output diagnostics |
ForACForDC 2amps2ampsresistive9(1ampinductive*) 25 amps(2cycles)25amps(10mSpeak) 7mA2mA 13mA2mA 65volts40volts 95volts40volts Zerocrossing––– OncepersecondOnce persecond 0.5 Hz+1mS1mS 2.5volts2.5volts 10volts10volts 25mA10mA 30mA10mA 40mA10mA 100mA10mA 50mA50mA |
15 amps at 35 C, 7.5 amps at 60C Internal electronic short circuit trip. 100ms(AC), 10ms (DC) long time trip ShortCircuit,Overload,NoLoad,Overtemp.,LossofI/OPower.Also, for blocks BBS100 and BBS 102 only: Failed Switch |