Mô đun Automation PLC Power Supply Module 8 – Channel Input 140 ARI 030 10
Redundant Power Supply Module Schneider Automation 8-Channel Input Module 140 ARI 030 10
Main
range of product Modicon Quantum automation platform
product or component type Analogue input module
Complementary
analogue input number 8
input type Differential
addressing requirement 9 input words
analogue input type
Temperature probe – 100…450 °C Pt 100, Pt 200, Pt 500, Pt 1000
Temperature probe – 200…850 °C Pt 100, Pt 200, Pt 500, Pt 1000
Temperature probe – 60…180 °C Ni 100, Ni 200, Ni 500, Ni 1000
Temperature probe 0.5 mA Ni 100, Ni 200, Ni 500, Ni 1000
Temperature probe 2.5 mA Pt 100, Pt 200, Ni 100, Ni 200
analogue input resolution 13 bits
input impedance >= 10 MOhm
absolute accuracy error 0.1 °C
linearity error
+/- 0.01 % full scale
+/- 0.5 °C
accuracy drift according to temperature
+/- 0.5 °C at 25 °C
+/- 0.9 °C at 0…60 °C
isolation between channels and bus
2500 V DC for 60 s
1780 V AC 47…63 Hz for 60 s
isolation between channels 300 Vrms AC
update time 1200 ms 3 wires
640 ms 2 wires/4 wires
fault type Broken wire
Overtacking scale
marking CE
local signalling
1 LED green bus communication is present (Active)
1 LED red external fault
8 LEDs green channel is turned on
8 LEDs red channel fault
bus current requirement 200 mA
power dissipation in W 1 W
module format Standard
product weight 0.3 kg
Environment
standards CSA C22.2 No 142 UL 508
product certifications CUL
FM Class 1 Division 2
resistance to electrostatic discharge
4 kV contact conforming to IEC 801-2
8 kV on air conforming to IEC 801-2
resistance to electromagnetic fields
10 V/m 80…1000 MHz conforming to IEC 801-3
ambient air temperature for operation 0…60 °C
ambient air temperature for storage -40…85 °C
relative humidity 95 % without condensation
operating altitude <= 5000 m
Offer Sustainability Sustainable offer status
Green Premium product RoHS (date code: YYWW)
Compliant – since 0822 – Schneider Electric declaration of conformity Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile Available End of life manual
Product end of life instructions Available
Contractual warranty
Warranty period 18 months
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Similar Products
140ACI03000, 57
140ACI04000, 69
140ACO02000, 119
140ACO13000, 129
140AII33000, 517
140AII33010, 539
140AIO33000, 551
140AMM09000, 153
140ARI03010, 79
140ATI03000, 91
140AVI03000, 105
140AVO02000, 139
140DAI34000, 231
140DAI35300, 239
140DAI44000, 247
140DAI45300, 255
140DAI54000, 263
140DAI54300, 271
140DAI55300, 279
140DAI74000, 287
140DAI75300, 295
140DAM59000, 497
140DAO84000, 389
140DAO84010, 399
140DAO84210, 409
140DAO84220, 421
140DAO85300, 431
140DDI15310, 173
140DDI35300, 181
140DDI35310, 189
140DDI36400, 197
140DDI67300, 207
140DDI84100, 215
140DDI85300, 223
140DDM39000, 473
140DDM69000, 485
140DDO15310, 317
140DDO35300, 327
140DDO35301, 337
140DDO35310, 347
140DDO36400, 357
140DDO84300, 367
140DDO88500, 377
140DII33000, 573
140DIO33000, 563
140DRA84000, 441
140DRC83000, 449
140DSI35300, 303
140DVO85300, 457
140SAI94000S, 589
140SDI95300S, 601
140SDO95300S, 613
Function
The Analog In 8 Channel Bipolar module accepts a mix of current and voltage inputs. Jumpers are required between the input and sense terminals for current inputs
Illustration
The following figure shows the 140 AVI 030 00 module and its components.
1 Model Number, Module Description, Color Code
2 LED Display
3 Fuse Cutouts
4 Field Wiring Terminal Strip
5 Removable Door
6 Customer Identification Label (Fold label and place it inside door)
NOTE: The field wiring terminal strip (Modicon #140 XTS 002 00) must be ordered separately. (The terminal strip includes the removable door and label.
External Wiring Recommendation
1. The user supplies the current and voltage sources (installation and calibration of
fuses are at the discretion of the user).
2. Use shielded signal cable. In noisy environnements, twisted shielded cable is
recommended.
3. Shielded cables should be connected to the PLC’s ground.
4. A Shield Bar (STB XSP 3000 and STB XSP 3010/3020) should be used to
connect the shielded cable to ground (see Quantum with Unity Pro, Hardware,
Reference Manual).
5. N / C = Not connected.
NOTE: When field wiring the I/O module, the maximum wire size that should be
used is 1-14 AWG or 2-16 AWG; the minimum size is 20 AWG
Warning
UNWIRED INPUTS CAUSE INVALID READINGS
When configured for voltage inputs (no jumper installed between INPUT(+) and ISENSE terminals), if a broken field wire occurs, readings will be non-zero and not predictable. The field wiring terminal strip must not be removed when the module is operating.
Failure to follow these instructions can result in injury or equipment damage
Danger
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Before accessing the fuses,
? Remove the power to the module (pre-actuators), and
? disconnect the terminal block.
? Always use a properly rated voltage sensing device at all line and load fuse clips
to confirm power is off.
Failure to follow these instructions will result in death or serious injury
The popular 140-ARI-030-10 Input Module is a part of the Modicon Quantum series. The Quantum 140ARI03010 RT Input Module provides 8 channels of 2-wire, 3-wire, and 4-wire RTD inputs. Temperment measurement data is provide to the Quantum CPU.
The 140ARI03010 specs include broken wire and short circuit detection. A quantum removable terminal strip (140XTS00200) is available and allows for easy maintenance. The 140ARI03010 weight is 0.3 kg.
Quantum backplanes, such as the 10 slot 140XBP01000, are sold separately. These come in 2, 3, 4, 6, 10, and 16 slot versions. Any quantum module can be used in any slot. A Quantum power supply is required in each rack, such as the 140CPS11420. The power supply provides logic power to all modules on the bus.
All Quantum I/O modules, including the 140ARI03010, are optically isolated from the bus, ensuring safe and trouble-free operation. The isolation allows modules to be hot swapped.
Optionally, you can inster mechanical keys between the I/O module and the terminal strip to ensure that the field wiring and the module type are properly matched. Key codes are unique for each module type. Key kits are shipped with each I/O module.
As an option, modules can be ordered with a conformal coating (designated as 140ARI03010C) which will protect the internal circuitry from corrosive gases such as Chlorine, Nitric Oxide, Hydrogen Sulfide, and Sulfur Dioxide.
For more info you can check out our product page. To get a 140ARI03010 price, delivery info, or if you have any questions, you can email or call 0086-.