Mô đun 5.04” Length Power Interface Module , Redundancy Diode Module IC200CPUE05
Redundant Power Supply Module GE Fanuc IC200CPUE05 CPUW/ ETHERNET CONFIGURABLE MEMORY
Built-in Station Manager functionality permits on-line diagnostic andsupervisory access through either Port 1 or via Ethernet. Station
Manager services include:
- An interactive set of commands for interrogating and controlling the station.
- Unrestricted access to observe internal statistics, an exception log, and configuration parameters.
- Password security for commands that change station parameters or operation.
- Use of the Station Manager function requires a separate computer terminal or terminal emulator.
Consumed exchanges may be configured. Supports up to 1200data ranges across all Ethernet Global Data exchanges, andsupports selective consumption of Ethernet Global Data exchanges.
Specifications
Size Width: 4.95” (126mm) – along DIN rail
Length: 5.04” (128mm)
Depth: 2.72” (69.1mm)
Program storage System flash, battery-backed RAM
Power Supply current consumption with no serial port converter or EZ
Program Store device 5V uses 220mA
Power Supply current consumption with serial port converter or EZ
Program Store device
5V uses: 320mA
3.3V uses: 570mA
Floating point yes
Boolean execution speed 0.8 ms/K (typical)
Realtime clock accuracy (for timerfunctions)
100ppm (0.01%) or +/- 9sec/day
Time of day clock accuracy 23ppm (0.0023%) or +/- 2sec/day @ 30C.
100ppm (0.01%) or +/- 9sec/day @ full temperature range
Embedded communications RS-232, RS-485, Ethernet
Configurable memory 64K bytes maximum
Ethernet Interface Specifications
Ethernet data rate 10Mbps (half- or full-duplex)
Ethernet port RJ-45, UTP
Number of SRTP server connections 8
Number of Ethernet Global Data
(EGD) configuration-based exchanges 32
EGD Exchange limits 100 data ranges per exchange 1400 bytes of data per exchange
EGD Time Synchronization NTP
EGD Selective Consumption yes
Load EGD configuration from PLC to programmer yes
Remote Station Manager over UDP yes
Local Station Manager (RS-232) via CPU Port 1
IC3600ALTD1 LINEAR TAPE
IC3600AMIA1 ANALOG MUX BD
IC3600AMIB1 CARD SINGLE END MULT
IC3600AMIP1 SINGLE END MULTIPLEX IC3600AMIP
IC3600AMLB1 IC3600AMLB
IC3600AMLG1 ANALOG MUX BD IC3600AMLG
IC3600AOAA1 3-STAGE-OPER-AMPL
IC3600AOAA2 OP AMP BOARD IC3600AOAA
IC3600AOAB1 5-STAGE-OPER-AMPL
IC3600AOAC1 OP AMP BOARD IC3600AOAC
IC3600AOAD1 SUMMING AMP BD
IC3600AOAF1 OP AMP BOARD
IC3600AOAF2 OPERATIONAL AMPL
IC3600AOAH1 OP AMP BOARD IC3600AOAH
IC3600AOAJ1 OP AMP
IC3600AOAK1 CARD
IC3600AOAL1 OP AMP BOARD IC3600AOAL
IC3600AOAL2 OP AMP BOARD
IC3600AOTM1 T/C DETECTOR BD
IC3600APAA1 POWER AMP BOARD
IC3600APAB1 POWER AMP BOARD IC3600APAB
IC3600APSG1 GAYNO-POWER-SUPPLY-C
IC3600ARFA1 LOGIC/ANALOG BD IC3600ARFA
IC3600ARHA1 ANALOG READ AND HOLD
IC3600ARHA2 READ/HOLD BOARD
IC3600ARHB1 ANALOG READ AND HOLD
IC3600ARHB2 READ/HOLD BOARD
IC3600ARTM2 R/T CONVERTER
IC3600ARTM4 R/T CONVERTER
IC3600AVAIA1
IC3600AVIA1 VOLTAGE ISOL BD IC3600AVIA
IC3600AVIB1 VOLTAGE ISOLATOR
IC3600AVIC1 VOLTAGE ISOLATOR
IC3600AVLA1 INPUT-VOLT-LIMITER
Supports up to 64 modules with up to 2048 I/O points
- Over 1 hour, backup battery protects memory contents upto 6 months.
- Backup battery has shelf life of 5 years when not in use.
- Run/Stop switch
- Floating point (real) data functions
The 10BaseT twisted pair cable must meet applicable IEEE 802 standards. Category 5 is recommended
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |