Mô đun 12MB Singlemode Redundant Power Supply Module Modicon 140CPU67861 Quantum HSBY
Redundant Power Supply Module Modicon 140CPU67861 Quantum HSBY 12MB Singlemode Schneider Electric
range of product |
Modicon Quantum automation platform
|
|
---|---|---|
product or component type |
Unity processor
|
mode of transmission |
Single mode
|
|
---|---|---|
clock frequency |
266 MHz
|
|
number of slots |
10
16 2 4 6 |
|
number of racks |
2 – local rack(s)
|
|
number of distributed I/O station |
63 station(s) – 1 rack(s) – 3 Modbus Plus network(s)
|
|
number of remote I/O station |
31 – 2 S908 remote I/O rack(s)
31 – 2 ethernet Quantum remote I/O rack(s) 31 – 2 ethernet X80 remote I/O rack(s) |
|
discrete I/O number |
Unlimited (31 drops of 28 slots max) – ethernet remote I/O
0 – local – forbidden in Hot Standby application 8000 inputs, 8000 outputs – distributed – per network Modbus Plus 31744 inputs, 31744 outputs – remote |
|
analogue I/O number |
Unlimited (31 drops of 28 slots max) – ethernet remote I/O
0 – local – forbidden in Hot Standby application 500 inputs, 500 outputs – distributed – per network Modbus Plus 1984 inputs,1984 outputs – remote |
|
application specific I/O |
Accurate time stamping
Counter High-speed interrupt inputs Serial link |
|
communication service |
Ethernet router
|
|
number of optional modules |
6 ( Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max)
|
|
maximum number of connections |
1 ( USB)
2 ( AS-Interface) – distributed 4 ( AS-Interface) – remote 6 ( Ethernet TCP/IP) – local 6 ( Modbus Plus) – local 6 ( Profibus DP) – local 1 ( Modbus) – RS232/485 Modbus/ASCII |
|
integrated connection type |
1 Modbus Plus with
1 Modbus with 1 USB with 1 optic fibre with Hot Standby protocol |
|
checks |
Hot standby
Process control |
|
memory description |
Internal RAM 11264 kB – 1536 kB for data
Expandable 8 MB – file storage with PCMCIA card |
|
switch function |
Key switch memory port on/off
|
|
application structure |
1 cyclic/periodic master task –
1 periodic fast task – forbidden in Hot Standby application 128 I/O interrupt tasks – forbidden in Hot Standby application 128 interrupt tasks – forbidden in Hot Standby application 32 timer interrupt tasks – forbidden in Hot Standby application 4 auxiliary tasks – forbidden in Hot Standby application |
|
number of instructions per ms |
10.28 Kinst/ms if 100 % Boolean
10.07 Kinst/ms if 65 % Boolean and 35 % numerical |
|
system overhead |
1 ms – master task
0.2 ms – fast task |
|
bus current requirement |
2760 mA
|
|
local signalling |
1 LED green for Ethernet activity (COM)
1 LED red for Ethernet collision |
|
electrical connection |
1 connector, connector type: RJ45 for connecting Modbus bus
1 female connector, connector type: SUB-D 9 for connecting to the Modbus Plus network 1 connector, connector type: LC (single mode fiber optic) for interconnecting primary and secondary PLCs up to 16 km |
protective treatment |
Conformal coating Humiseal 1A33
|
|
---|---|---|
product certifications |
CE
CSA GOST UL Misc (Marine) |
|
standards |
HazLoc
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
RoHS (date code: YYWW) |
Compliant – since 1625 – Schneider Electric declaration of conformity Schneider Electric declaration of conformity
|
|
REACh |
Reference not containing SVHC above the threshold
|
|
Product environmental profile |
Available
|
|
Product end of life instructions |
Available
|
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |
140CPU11302
140CPU11303
140CPU31110
140CPU43412A
140CPU43412AC
140CPU43412U
140CPU43412UC
140CPU53414B
140CPU53414BC
140CPU65150
140CPU65160
140CPU67160
140CPU65260
140CHS11000
140CHS21000
140CHS32000
140CHS41010
140CHS41020
140SHS94500
Application
1.Power industry, the elevator industry, parking, automobile, auto ancillary.
2.feed industry, aluminum smelting machines, refrigeration industry.
3.steel industry, combustion control systems, non-ferrous metal smelting.
4.glass industry, construction machinery, textile machinery, water treatment
Investigated to UL 61010-1, 3rd Edition and UL 61010-2-201, 1st Edition
Modicon M340 and M580 Digital and analog I/O modules Model(s) BMX-DAI followed by 1614, 1614H, 1615, or 1615H
Modicon M340 and M580 power supplies modules Model(s) BMXCPS followed by 2000, 3500, 3500H, 3540T, 2010, 3020, 3020H
Modicon M340 and M580, Digital and analog I/O modules Model(s) BMX-DAO 1615, BMX-DAO 1615H
Open type Box PC and Partial enclosure Display Model(s) HMIBMOxxxxxxxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
HMIBMPxxxxxxxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
HMIBMUxxxxxxxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
HMIPCCL2axxbxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
HMIPCCP2axxbxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
HMIPCCU2axxbxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
TM901BMPxxxxxxxxxxxx ,The a can be B, 6, D, 7 or J: The b can be A or D: The x can be any alphanumeric character, “-” or blank
Programmable Controllers, “Modicon M340 and M580” Model(s) TSXCAN followed by CA, CADD, CB, CBDD, CD or TDM, followed by 1, 2 or 3 digit number
TSXCAN, followed by KCDF followed by 2 or 3 digit number, followed by T or TP
Programmable Controllers, “Modicon M340, M580, Digital and analog I/O modules” Model(s) BMXDRC followed by 0805 or 0805H followed by 2 or 3 digit number, followed by T or TP