Bộ điều khiển YASKAWA Industrial Servo Drives SGD-04AP SERVOPACK 50/60hz With One Phase
Industrial Servo Drives YASKAWA SGD-04AP SERVOPACK Input 200-230v 50/60hz 1phase
Quick Details
Brand Name:Yaskawa
Model Number:SGD-04AP
Input Voltage: 200-230V
Input AMPS: 6
Input Frequency:50/60HZ
Input PH : 1
Output Power : 400W
Output Voltage: 0-230V
Output AMPS: 2.6
Output PH :3
Place of Origin:Japan
Efficiency:IE 1
OTHER SUPERIOR PRODUCTS
SGD-01AN+SGM-01A3NT14 |
SGD-01AHY130 |
SGD-01AS |
SGD-01BH |
SGD-01BP |
SGD-02AH |
SGD-02AHY500 |
SGD-02AN |
SGD-02ANY6 |
SGD-02AP |
SGD-02AS |
SGD-02BH |
SGD-02BP |
SGD-02BS+SGM-02B312 |
SGD-02BS+SGM-02B314 |
SGD-04AN |
SGD-04AN+SGM-04A3NT12 |
SGD-04AP |
SGD-04APY61 |
SGD-04AS |
SGD-04ASY52 |
SGD-04ASY53 |
SGD-08AH |
SGD-08AN |
SGD-08AP |
SGD-08APY61 |
SGD-08ASY25 |
Electrical Shock Hazard
Do not operate equipment with covers removed. Failure to comply could result in death or serious injury. The diagrams in this section may show drives without covers or safety shields to show details. Be sure to reinstall covers or shields before operating the drives and run the drives according to the instructions described in this manual. Always ground the motor-side grounding terminal. Improper equipment grounding could result in death or serious injury by contacting the motor case.
Do not perform work on the drive while wearing loose clothing, jewelry or without eye protection. Failure to comply could result in death or serious injury. Remove all metal objects such as watches and rings, secure loose clothing, and wear eye protection before beginning work on the drive.
Do not remove covers or touch circuit boards while the power is on. Failure to comply could result in death or serious injury.
Do not allow unqualified personnel to perform work on the drive. Failure to comply could result in death or serious injury. Installation, maintenance, inspection, and servicing must be performed only by authorized personnel familiar with installation, adjustment, and maintenance of AC drives.
Do not touch any terminals before the capacitors have fully discharged. Failure to comply could result in death or serious injury. Before wiring terminals, disconnect all power to the equipment. The internal capacitor remains charged even after the power supply is turned off. The charge indicator LED will extinguish when the DC bus voltage is below 50 Vdc. To prevent electric shock, wait at least one minute after all indicators are off and measure the DC bus voltage level to confirm safe level. Fire Hazard Tighten all terminal screws to the specified tightening torque. Loose electrical connections could result in death or serious injury by fire due to overheating of electrical connections. Do not use improper combustible materials. Failure to comply could result in death or serious injury by fire. Attach the drive to metal or other noncombustible material
.Do not use an improper voltage source. Failure to comply could result in death or serious injury by fire. Verify that the rated voltage of the drive matches the voltage of the incoming power supply before applying power
Terminals Terminal
Screws Tightening
Torque lb-in (N•m)
Possible Wire Sizes
AWG (mm2)
Recommended Wire Size AWG (mm2)
Wire Type
S1, S2, S3, S4, S5, S6, S7
SN, SC, SP, +V, A1, A2,
AC, MI, M2, M3, M4,
MA, MB, MC, FM, AC,
AM, R+, R-, S+, S-, IG
Phoenix type *3
4.2 to 5.3 (0.5 to 0.6)
Stranded wire: 26 to 16
(0.14 to 1.5) 18
(0.75) • Shielded, twisted-pair wire*1
• Shielded, polyethylene-covered,
vinyl sheath cable
E(G) M3.5 7.0 to 8.8
(0.8 to 1.0) 20 to 14
(0.5 to 2*2) 12 n(1.25)
*1. Use shielded twisted-pair cables to input an external speed command.
*2. Yaskawa recommends using straight solderless terminals on digital inputs to simplify wiring and improve reliability.
*3. Yaskawa recommends using a thin-slot screwdriver with a 3.5 mm blade width.