Bộ điều khiển Yasawa Electric Servo Controller 200-230VAC 100W 0.84Amp SJDE-01APA Mde in Japan
Yasawa Electric Servo Controller 200-230VAC 100W 0.84Amp SJDE-01APA Mde in Japan
DESCRIPTION
- Industrial Servo Drive
- ServoPack
- Servo Controller
SEPCIFICATIONS
Input Main Voltage: 200-230V
Input CONT Voltage: 200-230V
Input Mian PH: 1
Input Mian Frequency:50/60HZ
Input Mian Current : 1.3A
Input CONT Current : 0.25A
Output Power :100W
Output Voltage: 0-230V
Output Current: 0.84A
Output Frequency:0-300Hz
Output PH :3
Temperture: 0-55℃
Place of Origin:Japan
Efficiency:IE 1
SIMILAR PRODUCTS
SJDE-01APA
SJDE-02APA
SJDE-04APA
SJDE-04APA+SJME-04AMB41
SJDE-08APA
SJME-01AMA41
SJME-04AMA41
SJME-04AWA41
SJME-08AWA41
Servo Extensions – If the wire is too short to reach the board after installation, servo extenders in various lengths are available form Tam Valley Depot or at your local R/C hobby shop. Alternatively you can splice in extra lengths of wire. The servos draw little current so that any wire 26 gauge and above will work well. How many extensions can you add? In a test I was able to add 15 feet of 26 gauge extensions and the servos still worked well – at 20 feet the servos stopped working. A heavier gauge wire should allow longer extensions, although I haven’t made any tests.
Control Inputs The Mtry jumper is used to tell the board if momentary switches or toggle switches are being used. Make sure the jumper is correctly set or you will get unusual results. Fascia Controllers – The Octopus can use the same fascia controllers as the Quad servo decoder. Put on the Mtry jumper for proper operation. Toggles – The switch needs to be arranged so that it is open in one position and closed in the other (i.e. just like a light switch). You can use toggles, relays or lever switches for this. If you use a DPDT toggle, then the other side of the switch can be used to switch the frog polarity.
Momentary pushbutton – You can use a pushbutton (NO type) for the input. Each time the button is pushed, the turnout will change. Put the Mtry jumper on when using these. You can use several pushbuttons in parallel to have two or more stations controlling one turnout. You can use a Y cable with the fascia controllers to have two input stations both with indicator LEDS. Note: When considering where to mount the board it is better to have long servo leads than long control leads due to noise issues. Also do not bundle control wires together – keep them separated by a 1/4” or more to avoid crosstalk
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |