Bộ điều khiển 1500W 3 Phase Servo Motor Driver Servopack For Industrial SGDH-15AE-Y291
Industrial Servo Drives Yaskawa Servo Drives SGDH-15AE-Y291 1500W 3Phease
Quick Details
Brand Name:Yaskawa
Model Number:SGDH-15AE-Y291
Input Voltage:200-230V
Input Current: 9.5A
Input Frequency:50/60HZ
Input PH : 3
Series : Sigma 2 (Σ-II Series)
Output Power : 1.5KW
Output Voltage: 0-230V
Output Current: 11.6A
Output Frequency:0-300Hz
Output PH :3
Temperture: 0-55℃
Place of Origin:Japan
Efficiency:IE 1
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |
SGDH-08AE |
SGDH-08AE/08ADA |
SGDH-08AE-OY |
SGDH-08AE-SY202 |
SGDH-08DE |
SGDH-10AE |
SGDH-10AE/10ADA |
SGDH-10AE-0Y |
SGDH-10AE-R |
SGDH-10DE |
SGDH-15ADA |
SGDH15AE |
SGDH-15AE |
SGDH-15AE-OY |
SGDH-15DE |
SGDH-1AAE |
SGDH-20ADA |
SGDH-20AE |
SGDH-20AE-N2-RY49 |
SGDH-20AE-OY |
SGDH-20DE |
SGDH-30AE |
SGDH-30AE.50AE |
SGDH-30DE |
SGDH-50AE |
SGDH-50AE-RY342 |
SGDH-50AE-RY415 |
SGDH-50DE |
SGDH-60AE |
SGDH-75AE |
SGDH-75E |
SGDH-A3AE |
SGDH-A3BE |
SGDH-A5AE |
Use the servo amplifier within the ambient temperature range. When enclosed, the temperatures inside the cabinet must not exceed the specified range.
Speed Regulation = (no-load motor speed – full load motor speed) / rated motor speed x 100%
Forward is clockwise viewed from the non-load side of the servomotor, (counterclockwise viewed from the load and shaft end).
The built-in open collector power supply is not electrically isolated from the control circuit in the servo amplifier.
asic Specifications | Input Power Supply | Main Circuit1 | Three-phase (or single-phase) 200 to 230VAC +10% to -15%, 50/60 Hz, or single-phase 100 to 115VAC +10% to -15%, 50/60 Hz | |
Control Circuit1 | Single-phase 200 to 230VAC (or 100 to 115VAC) +10% to -15%, 50/60 Hz | |||
Control Mode | Three-phase, full-wave rectification IGBT PWM (sinusoidal commutation) | |||
Feedback | Serial incremental encoder, absolute encoder | |||
Location | Ambient/Storage Temperature2 | 0 to 55ºC / -20 to 85ºC | ||
Ambient/Storage Humidity | 90% or less (no-condensing) | |||
Vibration/Shock Resistance | 4.9m/s2/19.6m/s2 | |||
Structure | Base mounted (duct ventilation available as option) and flat mount type | |||
Speed/Torque Control Mode | Performance | Speed Control Range | 1 : 5000 (The lowest speed of the speed control range is the speed at which the servomotor will not stop with a rated torque load.) | |
Speed Regulation3 | Load Regulation | 0% to 100%: 0.01% max. (at rated speed) | ||
Voltage Regulation | Rated voltage ±10% : 0% (at rated speed) | |||
Temperature Regulation | 25 ± 25º°±C : 0.1% maximum (at rated speed) | |||
Frequency Characteristics | 400Hz (at JL = JM) | |||
Accel/Decel Time Setting | 0 to 10s (Can be set individually for acceleration and deceleration). | |||
Input Signal | Speed Reference | Reference Voltage4 | ±6VDC (variable setting range: ±2 to ±10VDC) at rated speed (forward rotation with positive reference); input voltage: ±12V (maximum) | |
Input Impedance | Approximately 14kW | |||
Circuit Time Constant | — | |||
Torque Reference | Reference Voltage4 | ±3VDC (Variable setting range: ±1 to ±10V) at rated torque (forward rotation with positive reference), input voltage: ±12VDC (maximum) | ||
Input Impedance | Approximately 14kW | |||
Circuit Time Constant | Approximately 47µs | |||
Contact Speed Reference | Rotation Direction Selection | Uses P control signal | ||
Speed Selection | Forward/reverse rotation current limit signals are used (1st to 3rd speed selection). When both signals are OFF, the motor stops or enters another control mode. | |||
Positioning Control Mode | Performance | Bias Setting | 0 to 450rpm (setting resolution: 1rpm) | |
Feed-forward Compensation | 0 to 100% (setting resolution: 1%) | |||
Position Complete Width Setting | 0 to 250 reference units (setting resolution: 1 reference unit) | |||
Input Signal | Reference Signal | Type | Sign + pulse train, 90º phase difference 2-phase pulse (phase A + phase B), or CCW + CW pulse train | |
Pulse Buffer | Line driver (+5V level), open collector (+5V or +12V level) | |||
Pulse Frequency | Maximum 500/200kpps (line driver/open collector) | |||
Control Signal | CLEAR (input pulse form identical to reference pulse) | |||
Built-in Open Collector Power Supply 5 | +12V (With built-in 1kW resistor) | |||
I/O Signals | Position Output | Output Form | Phases A, B and C: Line driver output Phase S: Line driver output (Only when absolute encoder is used) |
|
Frequency Dividing Ratio | Any | |||
Sequence Input | Servo ON, P control (or forward/reverse rotation in contact input speed control mode), forward rotation prohibited (P-OT), reverse rotation prohibited (N-OT), alarm reset, forward rotation current limit, and reverse rotation current limit (or contact input speed control) | |||
Sequence Output | — | Servo alarm, 3-bit alarm codes | ||
Configurable: (Any 3 of these signals) | Positioning complete (speed coincidence), servomotor rotating, servo ready, current limit, brake release, warning, and near position signals | |||
Built-in Functions | Dynamic Brake (DB) | Activated at main power OFF, servo alarm, servo OFF or overtravel | ||
Regenerative Processing | Incorporated. For 60 to 1A types, external regenerative resistor must be mounted. | |||
Overtravel (OT) Prevention | Motor decelerates or coasts to a stop, or is stopped by a dynamic brake. | |||
Protection | Overcurrent, overload, regenerative error, main circuit voltage error, heat sink overheat, power open phase, overflow, overspeed, encoder error, encoder disconnected, overrun, CPU error, parameter error. | |||
LED Display | POWER, CHARGE, five 7-segment LEDs (built-in digital operator functions) | |||
Analog Monitor (5CN) | Built-in analog monitor connector to observe speed, torque, and other reference signals Speed: 1V/1000rpm Torque: 1V/rated torque Pulses remaining: 0.05V/reference units or 0.05V/100 reference units |
|||
Communication | Interface | Digital operator (mount type or hand-held) RS-422A port such as person computer (RS-232C port can be used if some conditions are met). |
||
1 : N Communication | N can be up to 14 when RS-422A port is used. | |||
Axis Address Setting | Set via user parameters | |||
Functions | Status display, user constant setting, monitor display, alarm traceback display, jogging, autotuning, speed/torque reference signals, other graphing functions, etc. | |||
Others | Reverse rotation connection, home position search, automatic servomotor ID, DC reactor connection terminal for high power supply frequency control. |
- Use the servo amplifier within the ambient temperature range. When enclosed, the temperatures inside the cabinet must not exceed the specified range.
- Speed regulation is defined as follows:
Speed Regulation = (no-load motor speed – full load motor speed) / rated motor speed x 100% - Forward is clockwise viewed from the non-load side of the servomotor, (counterclockwise viewed from the load and shaft end).
- The built-in open collector power supply is not electrically isolated from the control circuit in the servo amplifier.