Mô đun Schneider standards 140DDO84300 7.5 A for 50 s Tsx Quantum Output Module 10-60v-dc
Schneider standards 140DDO84300 7.5 A for 50 s Tsx Quantum Output Module 10-60v-dc
Factory installed fuse pullers are standard on 30–100 A, NEMA Type 4/4X/5 stainless steel, NEMA Type 4X fiberglass reinforced polyester and
NEMA Type 12 or 12K switches; Available as a kit for field installation on 30–100 A, F Series switches, NEMA Type 1 and 3R switches
• 30–600 A switches are shipped with standard Class H fuse spacing. These switches will accept Class R fuses also; A field-installed rejection
kit is available, which when installed, rejects all but Class R fuses; See page 32 for Class R Fuse Kits
• Fuse load base(s) can be repositioned to accept Class J fuses on 30–600 A, 600 V switches and 100–600 A, 240 V switches;
600 A switches also require a mounting kit (catalog number H600J)
• Multiple padlock provision in OFF position (three 3/16-5/16 in. (4-7 mm) shank padlocks)
• Provisions to lock ON with one 3/8 in. (9 mm) padlock available factory installed, except for NEMA Type 7/9 and NEMA Type 4X fiberglass
reinforced polyester switches
• Tangential knockouts, where provided, lessen the need for conduit offset bends
• Lock-OFF provision is standard on all heavy duty safety switches
• NEMA Type 1 general purpose, indoor (ANSI-49 grey paint on cold rolled steel)
— Knockouts standard on 30–200 A enclosures; top, bottom and sidewalls
• NEMA Type 3R rainproof, outdoor (ANSI-49 grey paint on galvanneal steel)
— Knockouts standard on 30–200 A enclosures; bottom and sidewalls
• NEMA Type 4/4X/5 indoor or outdoor, watertight, dust-tight, and corrosion-resistant (NEMA Type 304 or NEMA Type 316 stainless steel)
• NEMA Type 4X indoor or outdoor, watertight and dust-tight, and corrosion-resistant (fiberglass reinforced polyester)
• NEMA Type 7/9 hazardous locations as defined in NEC Article 500 (copper free cast aluminum):
— Class I, Divisions 1 and 2, Groups C and D
— Class II, Divisions 1 and 2, Groups E, F and G
— Class III, Divisions 1 and 2
• NEMA Type 12 and 12K indoor, dust-tight, and drip-tight (ANSI-49 grey paint on galvanneal steel)
— NEMA Type 12 has no knockouts (also suitable for NEMA Type 3R outdoor use)
— NEMA Type 12K provided with knockouts 30–200 A enclosures; top, bottom and sidewalls
140CPU11302
140CPU11303
140CPU31110
140CPU43412A
140CPU43412U
140CPU53414B
140CPU65150
140CPU67160
TCSESM043F2CU0
TCSESM083F2CU0
TCSESM083F2CS0
TCSESM163F2CU0
TCSESM243F2CU0
140DDM39000
140CRA21110
140DAO84210
140DRC83000
TSXDEY16D2
140XBP00600
140NOE77101
140CRA93200
140CRP93200
140ACI03000
140ACO02000
140DDI35300
140DAI74000
140DDO35300
TCSESM083F2CUO
140ARI03010
140CPS21400
975750000
140CPU65260C
140CPS11420C
140DDI35300C
140DDO35300C
140ACI04000C
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC – |
Fanuc motor A0- | Yokogawa transmitter EJA- |
response time
<= 1 ms at state 0 to state 1
<= 1 ms at state 1 to state 0
maximum leakage current
1 mA 60 V
load inductance
Inductance(H) = 0.5/((current(A))² x (switching frequency(Hz)))
associated fuse rating
2 A each point
8 A per group
isolation between channels and bus
2500 Vrms DC for 1 minute
isolation between group
700 Vrms DC for 1 minute
protection type
Internal output protection by 8 A fuse per group
power dissipation
1 W + (1 V x total module load current)
marking
CE
local signalling
1 LED (green)bus communication is present (Active):
1 LED (red)external fault detected (F):
16 LEDs (green)input status:
bus current requirement
160 mA
module format
Standard
net weight
0.45 kg
Environment
product certifications
GOST
RMRS
FM Class 1 Division 2
C-Tick
standards
CSA C22.2 No 142
UL 508
resistance to electrostatic discharge
4 kV contact conforming to IEC 801-2
8 kV on air conforming to IEC 801-2
resistance to electromagnetic fields
10 V/m 80…2000 MHz conforming to IEC 801-3
ambient air temperature for operation
0…60 °C
ambient air temperature for storage
-40…85 °C
relative humidity
95 % without condensation
operating altitude
<= 5000 m
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
Yes
RoHS Regulation
RoHS declaration
Environmental Disclosure
Product Environmental Profile
Circularity Profile
End of Life Information
WEEE