Mô đun GE FANUC IC693CMM301 SERIES 90-30 PROGRAMMABLE LOGIC CONTROLLER (PLC)
đại lý IC693CMM301 | nhà phân phối IC693CMM301
GE FANUC IC693CMM301 SERIES 90-30 PROGRAMMABLE LOGIC CONTROLLER (PLC)
for IC693CMM301
Manufacturer GE Fanuc
Series Series 90-30
Part Number IC693CMM301
Product Type Genius Communications Module
Compatible Host PLCs Series 90-30 PLCs
Data Type Global Data
Maximum Data Rate 256 Bits (32 Bytes)
LEDs 2 (OK LED and COM LED)
Operating Temperature 32 to 140 degrees Fahrenheit
Storage Temperature -13 to 158 degrees Fahrenheit
Product Lifecycle Status* Discontinued/Obsolete
About IC693CMM301
The GE Fanuc IC693CMM301 module is a Series 90-30 Genius Communications Module. This module is made to communicate automatically. It makes “global data” communications possible between a GE Fanuc Series 90-30 PLC and as many as 7 additional devices with a Genius bus. Global data communications are communications that involve data which is transmitted repeatedly and automatically and which can be received by multiple devices with a shared database. Some of the devices that the IC693CMM301 Genius Communications Module can provide global data to include GE Series 90-30 PLCs, GE Series 90-70 PLCs, a computer that is used for programming and configuration applications, and another computer with a PCIM card that is used for data monitoring applications
The GE Fanuc IC693CMM301 Genius Communications Module can exchange a maximum of 32 bytes or 256 bits of data in total. It is easy to connect the IC693CMM301 Genius Communications Module to the backplate of the PLC that hosts it. This module has no jumpers or DIP switches, so it must be configured with a handheld programmer or with the proper system programming software. There are 2 LEDs on the IC693CMM301 Genius Communications Module. The OK LED means that the module has completed and passed its powerup test and that it is operating properly. The COM LED means that the module has been initialized by a Series 90-30 GE PLC and that the module is receiving bus communications. The COM LED will stay on after a successful startup and throughout operation unless there is a significantly high number errors, which will cause the COM LED to blink.
Introductionof Technology CO.,LTD
OTHER SUPERIOR PRODUCTS of Technology CO.,LTD
Yasakawa Motor, Driver SG- |
Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- |
Emerson VE-,KJ- |
Honeywell TC-,TK- |
GE Modules IC – |
Yokogawa transmitter EJA- |
of Technology CO.,LTD
1.
2.
3.
.
1.
2.
3.
* Passionate, experienced and highly-educated R & D and sales team;
:–