The DO820 is an 8 channel 230 V a.c./d.c. relay (NO) output module for the S800 I/O. The maximum output voltage is 250 V a.c./d.c. and the maximum continuous output current is 3 A. All outputs are individually isolated. Each output channel consists of optical isolation barrier, output state indication LED, relay driver, relay and EMC protection components. The relay supply voltage supervision, derived from the 24 V distributed on the ModuleBus, gives an error signal if the voltage disappears, and the Warning LED turns on. The error signal can be read through the ModuleBus. This supervision can be enabled/disabled with a parameter.
Features and benefits
- 8 channels for 230 V a.c./d.c. relay Normal Open (NO) outputs
- 8 isolated channels
- Output status indicators
- OSP sets outputs to predetermined state upon error detection
Type | Digital Output |
Signal specification | 230 V a.c. / d.c. (5 – 250 V a.c./d.c.), 3 A |
Article number | 3BSE008514R1 |
Number of channels | 8 |
Signal type | Relay (NO) |
HART | No |
SOE | No |
Redundancy | No |
High integrity | No |
Intrinsic safety | No |
Mechanics | S800 |
Isolation | Individually isolated, channel-to-channel and to circuit common |
Current limiting | Can be current limited by the MTU |
Maximum field cable length | 600 meters (656 yards) |
Event recording accuracy | -0 ms / +1.3 ms |
Rated insulation voltage | 250 V |
Dielectric test voltage | 2000 V a.c. |
Power dissipation | Typ. 2.9 W |
Current consumption +5 V Modulebus | 60 mA |
Current consumption +24 V Modulebus | 140 mA |
Current consumption +24 V external | 0 |
CE mark | Yes |
Electrical safety | IEC 61131-2, UL 508 |
Hazardous Location | – |
Marine certification | ABS, BV, DNV-GL, LR, RS, CCS |
Protection rating | IP20 according to IEC 60529 |
Corrosive atmosphere ISA-S71.04 | G3 |
Climatic operating conditions | 0 to +55 °C (Storage -40 to +70 °C), RH=5 to 95 % no condensation, IEC/EN 61131-2 |
Pollution degree | Degree 2, IEC 60664-1 |
Mechanical operating conditions | IEC/EN 61131-2 |
EMC | EN 61000-6-4, EN 61000-6-2 |
Overvoltage categories | IEC/EN 60664-1, EN 50178 |
Equipment class | Class I according to IEC 61140; (earth protected) |
Max ambient temperature | 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F) |
RoHS compliance | EN 50581:2012 |
WEEE compliance | DIRECTIVE/2012/19/EU |
Front LED’s | F(ault), R(un), W(arning), O(SP), Channel 1-8 Status |
Supervision | 24/12 V Relay power converter monitor |
Status indication of supervision | Module Error, Module Warning, Channel error |
Contact:
similar item we can supply:
3BSE031155R1 | BC810K02 | 3BSE031150R1 | PM865K02 |
3BSE018103R1 | CI853K01 | 3BSE050198R1 | PM866K01 |
3BSE030220R1 | CI854AK01 | 3BSE050199R1 | PM866K02 |
3BSE018106R1 | CI855K01 | 3BSE053241R1 | PM891K01 |
3BSE026055R1 | CI856K01 | 3BSE053242R1 | PM891K02 |
3BSE018144R1 | CI857K01 | 3BSE018172R1 | SB822 |
3BSE018135R1 | CI858K01 | 3BSE018173R1 | SM811K01 |
3BSE032444R1 | CI860K01 | 3BSC950193R1 | TB850 |
3BUA000037R1 | CI862K01 | 3BSC950194R1 | TB851 |
3BUA000111R1 | CI862K02 | 3BSC950263R1 | TB852 |
3BSE040795R1 | CI865K01 | 3BSE057022R1 | TB853 |
3BSE043660R1 | CI867K01 | 3BSC630049R1 | TC562 |
3BSE048845R1 | CI868K01 | 3BSC630197R1 | TK212A |
3BSE056767R1 | CI871K01 | 3BSC950192R1 | TK850V007 |
3BSE051129R1 | CI872K01 | 3BSC950262R1 | TK851V010 |
3BSE056899R1 | CI873K01 | 3BSC950201R1 | TK853V020 |
3BSE066485R1 | PM851AK01 | 3BSC950356R1 | TK855 |
3BSE066490R1 | PM856AK01 | 3BSE057021R1 | TK856 |
3BSE066495R1 | PM860AK01 | 3BSE049110R1 | 800xA |
3BSE018157R1 | PM861AK01 | 3BSE020512R1 | AI801 |
3BSE018160R1 | PM861AK02 | 3BSE008516R1 | AI810 |
3BSE018161R1 | PM864AK01 | 3BSE052604R1 | AI815 |
3BSE018164R1 | PM864AK02 | 3BSE008544R1 | AI820 |
3BSE031151R1 | PM865K01 | 3BSE036456R1 | AI825 |
Good Service in WTL:
> We offer high quality, fast delivery, competitive price for ABB Input Output Module.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate. If needed, please contact us for specific prices.
Liability:
WTL is not liable for any personal injury or property damage resulting from the use of this equipment. It is
buyer’s responsibility as to the safe handling & operation of this equipment and to verify equipment is
compliance to their machinery.
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive