Mô đun AB 1746-OV16 , SLC 500 Discrete Sinking Output Module , 1.2V At 0.5 A
AB 1746-OV16 , SLC 500 Discrete Sinking Output Module , 1.2V At 0.5 A
for 1746-OV16
Module Type | Discrete output module |
Series | SLC 500 |
Part Number/Catalog No. | 1746-OV16 |
Brand | AB |
Nom Input Voltage | 24VDC |
Input Voltage Range | 10-50 VDC |
Wiring configuration | Sink wiring configuration |
Backplane current consumption | 0.270 A |
Signal delay, max. resistive load | On = 0.1 ms; Off = 1.0 ms |
Continuous current per point | 0.50 A at 30 °C (86 °F); 0.25 A at 60 °C (140 °F |
Continuous current per module | 8.0 A at 30 °C (86 °F); 4.0 A at 60 °C (140 °F) |
On-state voltage drop, max | 1.2V at 0.5 A |
Surge current per point | 3.0 A for 10 ms |
Voltage Range | 10-50 Volts DC Sink |
Outputs | 16 |
Current/Output | 0.5 or 0.25 amps |
Current/Module | 8 or 4 amps |
Backplane Current (5 Volts) | 270 milliamps |
Applications | General Purpose DC Outputs |
Applications | High Current |
Step Response | 60 milliseconds in, 2.5 milliseconds out |
About 1746-OV16
The 1746-OV16 is an AB manufacture discrete output module. This module is provided with Sixteen (16) output channels in One (1) channel group. It is a sinking output module that delivers 10-50VDC output voltage range with minimum output of 24VDC. This module is ideally used to energize DC operated electrical loads such as relay coils, indicating and sounding devices.
The 1746-OV16 has a backplane current consumption of 0.270 Amperes at 5VDC with OFF-state leakage current of 1 mA and minimum load current of 1 mA as well. Each channel of this output module has a signal delay of 0.1 ms for ON to OFF transition and 1.0 ms for OFF to ON transition. The module’s continuous output current per point is 0.50 A at 30 °C (86 °F) and 0.25 A at 60 °C (140 °F) while the continuous output current per module is 8.0 A at 30 °C (86 °F) and 4.0 A at 60 °C (140 °F). This module exhibits a maximum On-state voltage drop 1.2V at 0.5 A.
The 1746-OV16 has a Surge current per point of 3.0 A for 10 ms that is repeatable once every 1 second 30 °C (86 °F) and 2 seconds repeatability at 60 °C (140 °F).
The 1746-OV16 is installed to an SLC 500 chassis. It is a single slot-width module that directly attached to a Modular style SLC 500 hardware. It comes with a removable terminal block that is pre-installed to the module. This terminal block may be removed from the module to implement easier and faster wiring activity.
It is a 16 channel output module that is compatible with the SLC 500 system. It has a heat dissipation per point of 0.388W and a total heat dissipation of 7.6W. The 1746-OV16 has a removable terminal block which allows you to connect or modify the wiring on the module easily. It has an operating voltage that ranges from 10-50V DC. It has a higher backplane current consumption (0.27 A) than the 1746-OV8 and the 1746-OVP16 modules. The 1746-OV16 has a maximum signal delay of 0.1ms in the On-state and of 1ms in the Off-state. It has a continuous current per output and per module of 0.5A and 8A at 30°C and 0.25A and 4A at 60°C, respectively. The 1746-OV16 has a maximum Off-state leakage of 1 mA and a maximum On-state voltage drop of 1.2V at 0.5A and 3A for 10ms maximum surge current per point.
The 1746-OV16 has a backplane current consumption of 0.270 Amperes at 5VDC with OFF-state leakage current of 1 mA and minimum load current of 1 mA as well. Each channel of this output module has a signal delay of 0.1 ms for ON to OFF transition and 1.0 ms for OFF to ON transition. The module’s continuous output current per point is 0.50 A at 30 °C (86 °F) and 0.25 A at 60 °C (140 °F) while the continuous output current per module is 8.0 A at 30 °C (86 °F) and 4.0 A at 60 °C (140 °F). This module exhibits a maximum On-state voltage drop 1.2V at 0.5 A.
The 1746-OV16 has a Surge current per point of 3.0 A for 10 ms that is repeatable once every 1 second 30 °C (86 °F) and 2 seconds repeatability at 60 °C (140 °F).
The 1746-OV16 is installed to an SLC 500 chassis. It is a single slot-width module that directly attached to a Modular style SLC 500 hardware. It comes with a removable terminal block that is pre-installed to the module. This terminal block may be removed from the module to implement easier and faster wiring activity.
It is a 16 channel output module that is compatible with the SLC 500 system. It has a heat dissipation per point of 0.388W and a total heat dissipation of 7.6W. The 1746-OV16 has a removable terminal block which allows you to connect or modify the wiring on the module easily. It has an operating voltage that ranges from 10-50V DC. It has a higher backplane current consumption (0.27 A) than the 1746-OV8 and the 1746-OVP16 modules. The 1746-OV16 has a maximum signal delay of 0.1ms in the On-state and of 1ms in the Off-state. It has a continuous current per output and per module of 0.5A and 8A at 30°C and 0.25A and 4A at 60°C, respectively. The 1746-OV16 has a maximum Off-state leakage of 1 mA and a maximum On-state voltage drop of 1.2V at 0.5A and 3A for 10ms maximum surge current per point.